New
VT335t Monitoring unit
Description
The VT335t Remote Monitoring Unit is a cutting-edge solution designed for comprehensive environmental monitoring and control across various applications. This unit excels in tracking critical parameters, including temperature, humidity, voltage, leakage, smoke, and airflow, making it ideal for environments like data centers, industrial facilities, and server rooms.
Key Features:
Environmental Monitoring: The VT335t continuously measures essential environmental factors to ensure optimal conditions, preventing equipment damage and operational failures.
I/O Control Capabilities: It functions as an I/O controller, enabling control over doors, fans, generators, UPS systems, and circuit breakers. This ensures efficient management of operational workflows.
Flexible Configuration: Users can manage up to 1,000 different elements, including notifications, triggers, timers, and logic schemes, allowing for tailored monitoring solutions that meet specific needs.
User-Friendly Interface: A built-in web interface provides access to virtual sensors, logic schemes, and diverse notification types, simplifying user interaction and enhancing accessibility.
Remote Connectivity: With a dedicated slot for an LTE modem, the VT335t ensures a reliable Ethernet connection, making remote monitoring and management convenient and efficient.
Use cases
- Agricultural Settings: Manage humidity and temperature in greenhouses to optimize crop growth.
- Rack / Cabinet manufacturers: Server rack or Electrical cabinet environmental monitoring of parameters adds an additional value when selling racks and adds technological innovation and value to the company.
- Data Centers: Monitor critical environmental conditions to safeguard sensitive equipment.
- Industrial Applications: Control operational equipment and automate responses to environmental changes.
Hardware specifications
- Grad A
- VT408 analog sensor extension unit adds more ports
- Plug & Play
- 5 level thresholds
- Hysteresis for alert delay if the sensor value jumps to fast
- Linear formula for sensor value adjustments
- Math element for calculating your own formulas
- Graphs, multi-graphs
- Ethernet 10/100 Base-T port, provides an Ethernet connection
- Connect digital CAN sensors in a daisy chain
- Connect CAN extensions
- Restart button
- Factory reset
- N-R switch
- Activity, Error, Alarm, CAN
- x2 12V relays
- Receive voltage free signals from devices and sensors
- E.g. door sensor, window sensor, UPS, diesel generators, circuit breakers, alarm system, control panels, and other industrial equipment.
- Connect KMS-30 access sensor
- 12V DC
- 12V DC terminal, 2P, pitch 3.81mm
- Control VT103 alarm beacon
- Control VT105 strobe light
- Control VT11 relay contact switch
- Control other 12V DC devices
- Temperature
- Voltage sensors for power supply inputs
- Chassis grounding
Extensions
VT740 LTE slot modem
Allows to receive and send SMS notifications (2G, 3G). Provides Ethernet reservation over LTE (4G).
Extension slot
VT485r Reader extension
Allows to connect readers, and keypads with OSDP protocol support.
or
VT485m Modbus extension
Allows to monitor up to 32 Modbus RTU devices/meters/sensors.
Advanced technology
From sensing to connecting, from data to the power that transforms the world, what we do matters.
Advanced protocols
Vutlan supports most popular communication protocols & adding more...
SNMP v1, v2c, v3
Simple Network Protocol for connecting multiple Vutlan units to a single DCIM, NMS, and Infrastructure monitoring software.
+
Modbus RTU,
Modbus TCP
Modbus serial communication protocol designed for industrial automation systems, and industrial meters.
+
OSDPv2 RS485
Open Supervised Device Protocol is an access control communications standard for readers, & keypads.
+
and other...
DHCP, HTTP, HTTPS, SMTP, FTP, Syslog, TLS, DynDNS, RADIUS, SSL, NTP, OpenVPN
Pushing limits
The most powerful monitoring and control systems in the world!
OS Linux
v.6.2
Processors
720 MHz, 2 Cores
Maximum sensors
100 physical sensors
Maximum elements
700 virtual elements
Embedded Web Interface
All Vutlan monitoring units come with a built-in multi-language Web Interface for monitoring and control of the device. Here you can configure notifications & alerts, logic schemes, user access permissions, sensors, and elements. You can also inspect sensor graphs, logs, or view cameras.
Previous
Next
Add more analog sensors using VT408 or VT408DIN
'VT408 Sensor extension unit' and 'VT408DIN Sensor extension unit" increase the number of analog sensors connected to any Vutlan monitoring unit. Each VT408 unit adds 8 analog sensors. Multiple VT408 units can be connected using a daisy CAN chain. Sensors connected to the extension unit appear in the system automatically.
Previous
Next
Add more dry contact inputs using VT440
'VT440 / Dry contacts extension unit' increases the number of dry contact input terminals connected to any Vutlan monitoring unit.
Each VT440 unit adds x32 terminals. Each VT440 unit + VT32 extension adds x64 terminals.
Multiple VT440 units can be connected using a daisy CAN chain.
Vutlan web interface offers a separate dry contact inputs panel for monitoring, control and configuration.
Previous
Next
Connecting CAN sensors
You can connect up to x32 CAN units in a CAN bus chain.
E.g. Each VT408 unit in a CAN bus chain adds 8 analog sensors.
E.g. Each VT440 unit adds x32 or x64 dry contact inputs to the system.
The additional power supply CAN12V-1A is needed only if the number of sensors in a CAN bus chain is more than 12 sensors. Supplies power for each additional group of 12 sensors.
Centralized Infrastructure Management Software using SNMP protocol
No matter how complex your IT infrastructure is, you can manage all assets using DCIM SNMP software, infrastructure management software.
Vutlan supports SNMP v1, SNMP v2c, SNMP v3. Hence the data from Vutlan monitoring units can be monitored from any SNMP managemnt software package.
Software specifications
- Full monitoring and control over IP
- Day / night cycles
- Manual season time setup
- Multi language web interface
- Floor map plan with layers and vectors
- System & group trees
- Logic schemes (IF, THEN, OR, AND events)
- No programming skills needed
- One time or repeated events
- Control equipment
- Send notifications
- Event triggers
- Group events
- Duplicator license is purchased separately
- For management of multiple devices
- Upload configuration and firmware
- USB camera (JPEG stream notifications)
- IP cameras (only view)
- Monitoring: modules, sensors, groups, map, USB web-cam & etc.
- CAN bus configuration
- Users DB
- Access keys DB
- Date and time configurations
- Network settings
- HTTP Server settings
- Logging settings
- Radius settings
- SNMP settings
- DynDNS
- Settings of update
- Settings of backup
- No SSH
- SSL cerrtificate
- OpenVPN client & server
- Routing
- NTP server
- Dynamic DNS
- Radius server
- Sensor graphs