Can be embedded inside VT440 (Dry Contacts extension unit). It has 32 dry contacts. Used to increase the number of dry contacts in VT440 from 32 to 64.
Ordered separately from VT440.
For installation inside of IT racks and cabinets, enclosures, doors, and windows. It is used to detect the opening of doors or windows, garage doors, rack doors, ie . in places , where it is necessary surveillance by means of opening the magnetic contact. It is but also compatible with many alarms other 3rd party brands. Detection is based on the separation of two magnetically interconnected parts, of one which is located on the frame door / window and the other on the door / window. This simple sensor of the basic set alarm requires no power supply, it is powered directly from the main unit alarm, simply connect it to dry contact inputs of the Vutlan monitoring system.
For installation inside of IT racks and cabinets, enclosures, doors, and windows. It is used to detect the opening of doors or windows, garage doors, rack doors, ie . in places , where it is necessary surveillance by means of opening the magnetic contact. It is but also compatible with many alarms other 3rd party brands. Detection is based on the separation of two magnetically interconnected parts, of one which is located on the frame door / window and the other on the door / window. This simple sensor of the basic set alarm requires no power supply, it is powered directly from the main unit alarm, simply connect it to dry contact inputs of the Vutlan monitoring system.
Can be embedded inside VT440 (Dry Contacts extension unit). It has 32 dry contacts. Used to increase the number of dry contacts in VT440 from 32 to 64.
Ordered separately from VT440.
Allows increasing the number of dry contacts connected to any Vutlan monitoring unit. Adds 32 dry contacts. Can be connected to any CAN port.
The number of dry contacts inside VT440 can be increased up to 64 with dry contacts module VT32.
The unit is used for environmental monitoring (e.g. temperature, humidity, voltage, leakage, smoke, airflow). It is also used as an I/O controller (e.g. door control, fans, generator, control panels, UPS, circuit breakers, alarms). Can use up to 1000 different elements - notifications, triggers, timers, logic schemes, sensors, dry contacts. Has built-in Web interface with virtual sensors, logic schemes, different types of notification, and control panels.
Has a slot for a "VT790 / LTE slot modem" (Ordered separately!) and a 2.5" HDD. This is the fastest and most powerful Vutlan monitoring unit. It has two order options:
VT960i with x1 power inlet.
VT960ii with x2 power inlets, providing a redundant power supply for A&B power distribution systems (e.g. data centers).