MenuBack
-
Products
-
-
-
VT225t
Room monitoring unit
-
-
VT336t
Industrial monitoring unit
-
-
VT335G
Monitoring Unit
-
-
VT825G
Data Center Monitoring Unit
-
-
VT855G
Corporate Monitoring Unit
-
-
-
-
LR800
LoRa Gateway & Server
-
-
LR490
Temperature & Humidity sensor
-
-
LR530
Access sensor
-
-
-
-
VT-PDU 4PS
Switched by Outlet PDU
-
-
VT-PDU 4MS
Switched & Metered-by-outlet PDU
-
-
VT608t
Switched PDU with 8 outlets
-
-
VT604t
Switched PDU with 4 outlets
-
-
-
-
VT7670
LTE 4G slot modem
-
-
VT485m
Modbus RTU extension
-
-
VT-ACCU
Rechargeable backup
-
-
VT11
Relay Output
-
-
VT12
Relay Module
-
-
-
-
Alarm becons & Strobe lights
-
-
Cameras
-
-
Mounting brackets
-
-
Antennas
-
-
Readers
-
-
-
-
-
-
Duplicator program
-
-
Web Interface
-
-
SNMP
Managment software
-
-
-
-
Extended 1 Year Warranty
-
-
Extended 2 Year Warranty
-
-
-
Solutions
-
Support
-
How to buy
-
ABOUT US
K6D DC Current meter
€88.50 Tax included

Description
The K6D DC is a simple open-loop DC ammeter capable of measuring currents from 0A to 50, 100, 200, 300, 400, 500A. It connects to the monitoring system via the VT405 transceiver. This plug-and-play transceiver easily connects to any analog port of Vutlan monitoring devices.
-08.webp)
-07.webp)
Use cases
- DC Power Distribution Monitoring: Measures load current from DC Hall effect transducers installed on battery strings, DC busbars, and distribution lines, enabling remote supervision of power consumption, overload detection, and circuit health.
- Battery System Current Monitoring: Monitors charge and discharge currents in battery banks, UPS systems, and energy storage systems to track performance, detect abnormal current flow, and optimize battery life.
- DC Equipment Monitoring: Supervises telecom rectifiers, DC motors, solar controllers, EV chargers, and industrial DC-powered equipment to detect operational changes, unexpected load variations, and fault conditions. You’re out of messages with the most advance
Order Options / Models
K6D DC 50:
Rated input: 50A
Measured range: 0-50 Adc
K6D DC 100:
Rated input: 100A
Measured range: 0-100 Adc
K6D DC 200:
Rated input: 200A
Measured range: 0-200 Adc
K6D DC 300:
Rated input: 300A
Measured range: 0-300 Adc
K6D DC 400:
Rated input: 400A
Measured range: 0-400 Adc
K6D DC 500:
Rated input: 500A
Measured range: 0-500 Adc
Required Components

VT405 Current Tranceiver
The VT405 current transceiver bridges the measured data from the K6D DC transducer to the Vutlan monitoring system.
Technical Specifications
Used for:
Measure Direct Current
Rated input (Adc):
50A, 100A, 200A, 300A, 400A, 500A
(see order options)
(see order options)
Measured range:
0-50, 0-100, 0-200, 0-300, 0-400, 0-500 Adc
(see order options)
(see order options)
Rated output:
0-5Vdc
Load resistance:
≤250 Ω (for measured range 0-50, 0-100, 0-200 Adc)
≥10 KΩ (for measured range 0-300, 0-400, 0-50 Adc)
≥10 KΩ (for measured range 0-300, 0-400, 0-50 Adc)
Offset current:
≤±0.1 mA (for measured range 0-50, 0-100, 0-200 Adc)
≥15 mV (for measured range 0-300, 0-400, 0-50 Adc)
≥15 mV (for measured range 0-300, 0-400, 0-50 Adc)
Supply Voltage:
+12 Vdc
Accuracy:
≤±1.0 %
Linearity error:
≤±1.0 %
Response time:
≤ 20 mS
Power consumption:
≤ 50 mA (for measured range 0-50, 0-100, 0-200 Adc)
≤ 20 mA (for measured range 0-300, 0-400, 0-50 Adc)
≤ 20 mA (for measured range 0-300, 0-400, 0-50 Adc)
Bandwidth:
DC-2.0KHz
Insulation voltage:
AC 2.5KV 50Hz 1min
Operating temperature:
-10~ +70°C
Storage temperature:
-25~ +85°C
Through hole:
21 mm
Phase:
Single
Coil Structure:
Toroidal
Coil Number:
Auto-transformer
Net Weight:
67g
Outputs:
4 pin terminal, pitch 3.81mm,
G: ground
M: 0-5V output
G: Ground
+: +12V DC power input
G: ground
M: 0-5V output
G: Ground
+: +12V DC power input
HS Code:
9030 33 100